Non insulated terminal crimper – firm bites on bare terminals

Insulated vs. Non-Insulated Terminals: Techniques for Crimping Each Type

Reading Insulated vs. Non-Insulated Terminals: Techniques for Crimping Each Type 6 minutes Next Battery Cable Terminal Getting Hot? How to Tell a Bad Crimp from a Loose Connection or Wrong Cable Size
HAISSTRONICA QUICK CHOICE

Insulated or Non-Insulated?

Choose the terminal first. Match the crimper second. Use the four job conditions below to make the right call.

WATERPROOFING

Heat shrink: sealed protection
Non-insulated: needs added protection

SPACE

Heat shrink: slightly larger
Non-insulated: compact fit

VIBRATION

Heat shrink: added strain relief
Non-insulated: less built-in support

COST

Heat shrink: more protection
Non-insulated: lower cost per joint

The Short Answer — When to Choose Each, and How Crimping Differs

When to use non-insulated vs. insulated? In a nutshell, non-insulated crimp terminals are best when electrical isolation isn’t a concern (e.g. inside a controlled panel or for a ground connection) and you want a compact, economical solution. They’re simply bare metal connectors, so they’re smaller and cheaper – ideal if you plan to add your own insulation (like heat shrink) or if the connection is in a low-risk location. On the other hand, insulated crimp terminals (vinyl, nylon, or heat-shrink types) are preferred whenever there’s any chance of shorts or environmental exposure. Their built-in insulation protects against accidental contact and moisture, which is critical if the wire might touch other conductors or face vibration, chemicals, or weather.

How does crimping differ? The act of crimping – using a wire crimper tool to compress the terminal onto the wire – differs mainly in the crimping die design and technique for each type. Non-insulated crimping tools often have a sharpened indent or “nubbing” on the die that bites into the barrel for a tight crimp. This creates a firm mechanical lock on the bare metal, but it would puncture or damage an insulated terminal’s plastic sleeve if used incorrectly. That’s why dedicated insulated terminal crimpers use a different jaw profile – typically a rounded or oval crimp that squeezes the internal metal ferrule without cracking the insulation. In practice, this means you should never crimp an insulated connector with a non-insulated crimper die, as it can pierce the insulation and expose bare metal (a safety hazard). The reverse (crimping a non-insulated connector with an insulated-type crimper) isn’t as destructive, but it often won’t form as tight a bond. Proper wire crimping tools will be labeled for each type – for instance, some hand crimpers have separate markings or slots for “INS” (insulated) and “NON” (non-insulated). The shape and size of the crimp result are deliberately different for insulated vs. uninsulated terminals to ensure a secure crimp without damage.

Another difference is the possibility of double crimping on certain insulated terminals. Many nylon-insulated connectors allow you to crimp twice – once on the bare wire and a second time on the insulated part of the wire – to add strain relief. This two-stage crimp improves pull strength and vibration resistance.

The Haisstronica AWG 22–10 Ratchet Crimping Tool features an adjustable ratchet for compatible heat shrink terminals.

View the AWG 22–10 Ratchet Crimping Tool →

Prep Work — Wire Size, Strip Length, and Fit

No matter which type of terminal you crimp, proper preparation is key. Before you even pick up your wire crimping tools, take a moment to prep the wire and terminal:

  • Match the Wire Gauge to the Terminal: Always use a terminal size that matches your wire’s gauge. Insulated terminals make this easy with standardized color codes – red for 22–16 AWG, blue for 16–14 AWG, and yellow for 12–10 AWG. For example, a blue insulated spade connector is made for a 16 or 14 gauge wire. Using the correct size ensures the wire fills the crimp barrel properly. A mis-matched size can lead to a loose crimp (too small wire in a large barrel) or an over-crimp that cuts strands (wire too big for the connector). With non-insulated crimp connectors, check the product specs or labeling for the supported AWG range, since there’s no color plastic to signal the size. The goal is a snug fit between wire and barrel.

  • Strip the Right Length of Insulation: Using a wire stripper, remove just enough insulation so that the bare wire fits fully into the terminal barrel. Typically about 1/4 inch (6 mm) of bare wire is needed for small terminals (up to ~1/2 inch for larger gauges). Do not strip too much – you don’t want excess bare copper sticking out past the connector, which could cause shorts. Conversely, stripping too little means the insulation might get caught under the crimp and the wire won’t seat fully. A good rule of thumb is that the stripped wire should be just long enough that when inserted, no bare conductor is visible and the wire’s own insulation is right up against the back end of the terminal barrel.

  • Ensure a Clean Fit Before Crimping: After stripping, insert the wire into the terminal before crimping to check the fit. All the bare strands should go neatly inside the barrel – none should splay out. The wire should feel snug, with little to no gap. If it’s a non-insulated terminal, you can visually confirm that the wire fills the barrel and reaches the end. If it’s insulated, make sure the wire goes in until it bottoms out (many insulated connectors have a metal stop inside). This is also a good time to orient any seam on the terminal correctly (for crimpers with indent dies: typically place the barrel’s seam opposite the indentor, so the solid side gets the force). Finally, position the terminal in the crimping tool’s appropriate slot before squeezing. For insulated terminals, use the color-coded die that matches (e.g. red, blue, or yellow) and align the tool so its jaw will press on the metal barrel beneath the insulation. For non-insulated, pick the die opening that best matches the barrel size. 

Explore Our Heat Shrink Terminal Collection

Haisstronica shrink wrap wire connectors kit with 520 pieces for comprehensive electrical projects.

Find heat shrink connectors in different terminal styles and wire sizes for your wiring projects.

Shop Heat Shrink Terminals →

Our Top User-friendly Picks

Choose the best crimping tool for heat-shrink terminals: hardened steel, anti-slip grips, and a calibrated ratchet. Engineered as heavy duty crimping tools, it maintains alignment under load for uniform barrels. Add a wire sleeve crimper die to finish strain-relief like a pro.

👏 You may be interested in the following:

Wire Crimping Tool
Wire Crimping Tool

Use Code: --Blog-- for --15%-- off on your order

  • Available For Insulated Nylon Connectors and Electrical Wire Connectors
  • Precision Ratchet Structure- Features a comfortable grip and solid ratchet action for smooth crimp tool action and good release.
  • The jaws of the haisstronica wire crimper tool forged with precision technology can complete a firm crimp at one time.
$30.99 USD
View details
Wire Crimping Tool
Wire Crimping Tool
$30.99 USD

Leave a comment

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Free Standard Shipping

Fast shipping within 2 business days